16kW M-Thermal Mono(50Hz)

All in one solution for any application

MODEL NUMBER: MHC-V16W/D2RN1

  • Heating, cooling, floor heating and sanitary hot water
  • Built-in hydraulic kit, integrated design
  • High efficiency and wide operating range
  • Flexible operation and more comfort

Color: White

Features

M-Thermal Mono type has the integrated design with built-in hydraulic kit and only water pipe is needed to be installed at site. It not only supplies hot water for fan coil, floor heating system, sanitary water tank, but is also compatible with the solar collector, gas furnace, boiler and other heat sources.

High efficiency and wide operating range

DC inverter technology to guarantee optimal operational reliability and efficiency. Offers heating capacity of 80% at -7°C thanks to the large heat exchanger and large compressor. Built-in backup electric heater for additional heating during extremely cold weather. The capacity of the backup electric heater is customizable and the output capacity is adjustable. Heating, cooling and domestic hot water: a total heat solution. Wide ambient temperature and water outlet temperature operating ranges.

Easy installation and easy maintenance

All hydronic components are located within the outdoor unit. Refrigerant system entirely contained within outdoor unit - no additional refrigerant piping required. Compact structure, easy for transportation and installation. Two-door design for easy access to internal components for easy maintenance.

Flexible operation and more comfort

Weather dependent operation with climate correlation to ensure absolute comfort. Two zones control more flexibility. Priority setting function and multi modes choice. Special functions such as air purge, preheating for floor and floor drying up.

Specifications
General
Type M-Thermal Mono
Specification
Power Supply (Ph-V-Hz) 380-415/3/50
Heating Capacity (kW) 16.30
Cooling Capacity (kW) 15.26
Net dimensions (W×H×D)(mm) 1404×1414×405
Packed dimensions (W×H×D)(mm) 1475×1580×440
Net weight(kg) 177
Gross weight(kg) 198
Ambient temp.operation range(Cooling)(℃) -5~46
Ambient temp.operation range(Heating)(℃) -20~35
Ambient temp.operation range(DHW)(℃) -20~43
Water outlet temp. range(Cooling)(℃) 5~25
Water outlet temp. range(Heating)(℃) 25~60
Water outlet temp. range(DHW)(℃) 40~60